;SMC Gateway Unit EX500-GPR1A-X8 HW I/O=64/64 ;Name: Smc_140C.gsd ;Version: 1.0 ; ;Date: 14.04.03 ; #Profibus_DP GSD_Revision = 2 ;Version ID of the GSD file format Vendor_Name = "SMC Pneumatic" ;Manufacturer's Name Model_Name = "EX500-GPR1A-X8" ;Manufacturer's designation of DP device Revision = "V1.0" ;Revision version of the DP device Ident_Number = 0x140C ;Device type of the DP device Protocol_Ident = 0 ;Protocol ID of the DP device(0:PROFIBUS DP) Station_Type = 0 ;DP device type(0:DP Slave) FMS_supp = 0 ;Not an FMS/DP mixed device Hardware_Release = "2" ;Hardware release of the DP device Software_Release = "1" ;Software release of the DP device ; 9.6_supp = 1 ;Supports the baudrate 9.6 kBaud 19.2_supp = 1 ;Supports the baudrate 19.2 kBaud 45.45_supp = 1 ;Supports the baudrate 45.45 kBaud 93.75_supp = 1 ;Supports the baudrate 93.75 kBaud 187.5_supp = 1 ;Supports the baudrate 187.5 kBaud 500_supp = 1 ;Supports the baudrate 500 kBaud 1.5M_supp = 1 ;Supports the baudrate 1.5 MBaud 3M_supp = 1 ;Supports the baudrate 3 MBaud 6M_supp = 1 ;Supports the baudrate 6 MBaud 12M_supp = 1 ;Supports the baudrate 12 MBaud ; ;This is time a responder needs as a maximum at a baudrate to respond ;to a request message(refer to EN 50170 Part 8-2 Clause 8.8) MaxTsdr_9.6 = 15 MaxTsdr_19.2 = 15 MaxTsdr_45.45 = 15 MaxTsdr_93.75 = 15 MaxTsdr_187.5 = 15 MaxTsdr_500 = 15 MaxTsdr_1.5M = 25 MaxTsdr_3M = 50 MaxTsdr_6M = 100 MaxTsdr_12M = 200 ; Redundancy = 0 ;Supports redundant transmission engineering(0:No) Repeater_Ctrl_Sig = 0 ;The bus connector signal CNTR-P is specified(0:Not connected) 24V_Pins = 0 ;The bus connector signal M24V and P24V is specified(0:Not connected) ; Freeze_Mode_supp = 1 ;Supports the Freeze mode(1:True) Sync_Mode_supp = 1 ;Supports the Sync mode(1:True) Auto_Baud_supp = 1 ;Supports automatic baudrate recognition(1:True) Set_Slave_Add_supp = 0 ;Supports the function Set_slave_Add(1:True) Fail_Safe = 1 User_Prm_Data_len = 5 ;The length of User_Prm_data User_Prm_Data = 0x00,0x00,0x00,0x00,0x00 ;Specifies the default value for User_Prm_data Min_Slave_Intervall = 1 ;The minimum interval time(Time Base:100 us) ; Modular_Station = 0 ;0:compact device Slave_Family = 9 ;9:Gateway Implementation_Type = "SPC3" Max_Diag_Data_Len = 13 ;The maximum length of the diagnostic information Unit_Diag_Bit(0) ="Comm. Port A :Not connect" Unit_Diag_Bit(1) ="Comm. Port B :Not connect" Unit_Diag_bit(2) ="Comm. Port C :Not connect" Unit_Diag_bit(3) ="Comm. Port D :Not connect" Unit_Diag_bit(4) ="Sol. Power :Drop(Power < 20V)" ; Module = "DP-Kompaktgeraet 64A/64E" 0x17,0x27 EndModule