$**************************************************************************** $ $ File: EX250-SCN1.EDS $ $ $ Author: Limin Cheng $ $ Date: 12.16.04 $ $**************************************************************************** $ $ ATTENTION: $ $ Changes in this file can cause configuration or communication problems. $ $**************************************************************************** $ $ Changes: $ $ Version Date Name Description $ ------------------------------------------------------------------------- $ $ 1.1 09.17.04 LC adapted from IN574-28.eds $ $**************************************************************************** [File] DescText = "EDS-File for EX250-SCN1"; CreateDate = 03-07-2003; CreateTime = 00:00:00; ModDate = 12-16-2004; ModTime = 13:53:00; Revision = 1.2; [Device] VendCode = 7; VendName = "SMC Corp."; ProdType = 7; ProdTypeStr = "General Purpose Discrete I/O"; ProdCode = 2501; MajRev = 1; MinRev = 2; ProdName = "Valve Manifold SIU"; Catalog = "EX250-SCN1"; [Device Classification] Class1 = ControlNet; [Port] Port1 = ControlNet,"Port1", "20 F0 24 01",2; [Params] Param1 = 0, $ first field shall equal to 0 , $ Link Path Size , $ Link Path 0x0000, $ Descriptor 0xC7, $ Data Type, UINT 2, $ Data Size in UINTs "Assembly Output Size", $ Parameter Name "", $ Unites String "", $ Help String 0, $ Minimum Value 65535, $ Maximum Value 0, $ Default Value 0, $ Scaling Multiplier, OPT 0, $ Scaling Divider, OPT 0, $ Scaling Base, OPT 0, $ Scaling Offset, OPT 0, $ Multiplier Link, OPT 0, $ Divisor Link, OPT 0, $ Base Link, OPT 0, $ Offset Link, OPT 0; $ Decimal Precision, OPT Param2 = 0, $ first field shall equal to 0 , $ Link Path Size , $ Link Path 0x0000, $ Descriptor 0xC7, $ Data Type, UINT 2, $ Data Size in UINTs "Assembly Input Size", $ Parameter Name "", $ Unites String "", $ Help String 0, $ Minimum Value 65535, $ Maximum Value 0, $ Default Value 0, $ Scaling Multiplier, OPT 0, $ Scaling Divider, OPT 0, $ Scaling Base, OPT 0, $ Scaling Offset, OPT 0, $ Multiplier Link, OPT 0, $ Divisor Link, OPT 0, $ Base Link, OPT 0, $ Offset Link, OPT 0; $ Decimal Precision, OPT [Connection Manager] Connection1 = 0x84010002, $ Trigger and Transport $ Mask Bit Assignment: $ 0-15 = supported transport classes (class 1) $ 16 = cyclic (1 = supported) $ 17 = change of state (0 = not supported) $ 18 = on demand (0 = not supported) $ 19-23 = reserved (must be zero) $ 24-27 = exclusive owner $ 28-30 = reserved (must be zero) $ 31 = server 1 (don't care for classes 0 and 1) 0x44240405, $ Connection parameters $ Mask Bit Assignment: $ 0-3: point/multicast & priority & realtime format $ 0 = O=>T fixed (1 = supported) $ 1 = O=>T variable (0 = not supported) $ 2 = T=>O fixed (1 = supported) $ 3 = T=>O variable (0 = not supported) $ 4-5 = obsolete - value not changed for backwards compatibility $ 6-7 = obsolete - value not changed for backwards compatibility $ 8-10 = O=>T header (4 byte run/idle) $ 11 = reserved (must be zero) $ 12-14 = T=>O header(0 = Connection is pure and modeless) $ 15 = reserved (must be zero) $ 16-19 = O=>T point-to-point $ 20-23 = T=>O multicast $ 24-27 = O=>T priority: scheduled $ 28-31 = T=>O priority: scheduled , $ O=>T RPI, no constraints 4, $ O=>T Size, using Param1 , $ O=>T format, not specified , $ T=>O RPI, no constraints 6, $ T=>O size, using Param2 , $ T=>O format, not specified , $ config #1 size, NO , $ config #1 format, NO , $ config #2 size, NO , $ config #2 format, NO "Data, In/Out - Enhanced", $ Connection Name String "Assembly Object In/Out Data", $ Help String "20 04 24 06 2C 24 2C 06"; $ Path, class 4, instance 6, $ connection point 0x24 is consumming $ Connection point 0x06 is producing $**************************************************************************** $ EOF $****************************************************************************